REVOLUTIONARY ENERGY SAVINGS FOR THE BUILT ENVIRONMENT
The world-proven range of oil-free centrifugal chillers from Smardt.
Smardt oil-free centrifugal chillers offer the highest IPLV energy efficiencies and the lowest lifetime operating costs in their capacity ranges - 200 kW through 8150 kW in water cooled, 200 kW through 1800 kW in air cooled and 200kW through 1320kW in evaporatively cooled.
The worldwide operations of the Smardt Chiller Group offer a greater depth of technical support and greater experience than anyone else in the world with oil-free centrifugal technology and its successful delivery of lifetime energy cost savings.
WATER CHILLED COOLERS
Smardt’s water cooled chiller range – 200 kW through 8150 kW - is designed for a 30-year operating life, with lifetime operating costs the lowest in the market.
No oil, flooded shell-and-tube evaporation, low power consumption, low maintenance costs (even lower with remote monitoring) and high reliability with only one main moving part.
Smardt and PowerPax work hard to achieve simplicity of design and operation – reflected in low operating costs, and supported by the integration of PowerPax electronic expansion valves and the optional use of load balancing valves at very low loads.
Field reliability since 2002’s introduction has been outstanding – not surprising when you consider that some 80% of all chiller problems in the field are due to failures in compressor oil return. And these Smardt chillers use no oil.
The growing fraternity of Turbocor-trained engineers and technicians suggests that total maintenance costs for oil-free chillers run at well under half the costs of traditional lubricated chillers. This assessment may be very conservative.
Smardt's standard 200 - 8150 kwR water-cooled chillers deliver an IPLV of 9.5 kW/kW under AHRI conditions. Compare the energy savings with your currently installed equipment.
Serviceability
Always important in minimizing operating costs, service access is swift and simple, as is access to operating history through remote monitoring. Operating history, compressor and chiller set points are all accessible remotely by trained and authorized service personnel.
Integration through MODBUS with building management systems is standard, as is connectivity with most industry-standard protocols.
Custom design and production capacity
The group’s design engineers are happy to resolve special equipment design challenges for you, but please allow some extra time and, possibly, some extra cost for these.
High-efficiency direct expansion condensing units, heat recovery and free cooling applications can all be supplied competitively, as can special materials for use in aggressive environments.
Marine water boxes, corrosion protection and other options are available and can be explored on request.
Redundancy
Use of multiple compressors allows unusual redundancy safeguards; however, if multiple circuits are indicated, these can be designed in and supplied.
Model Description | Brand | Nominal Capacity ton/kW | COP | Refrigerant Used | Compression Designation | Compressor Type | Hertz |
---|---|---|---|---|---|---|---|
WA026 to WA225 Economised | Smardt | 60RT - 400RT 211 - 1,407 kW | 6.311 | R-134A | TT300; TT350 | CENTRIFUGAL | 50 |
WA040 to WA145 Economised | Smardt | 100RT - 400RT 352 - 1,407 kW | 6.311 | R-134A | TT400 | CENTRIFUGAL | 50 |
WA064 to WA260 Economised | Smardt | 150RT - 850RT 527 - 2,990 kW | 6.311 | R-134A | TT500; TT751 | CENTRIFUGAL | 50 |
WA180 to WA400 Economised | Smardt | 500RT - 1000RT 1,759 - 3,517 kW | 6.311 | R-134A | TT400 | CENTRIFUGAL | 50 |
WA300 to WA400 Economised | Smardt | 900RT - 1050RT 3,165 - 3,693 kW | 6.311 | R-134A | TT500; TT700 | CENTRIFUGAL | 50 |
AIR COOLERS
Air-cooled chiller range – 200 kW to 1800 kW
The Smardt air-cooled range offers the smallest footprint on the market, the quietest operation on the market (in both standard and low-noise configurations) and the highest air-cooled operating efficiencies on the market.
The standard SBS condenser coils are electrophoretically dipped with proven salt spray resistance exceeding 6000 hours to ASTM B117. Stainless steel fasteners are utilised throughout the condenser construction. Additionally, UV and colour stabilised High Molecular Weight Polyethylene (HWMPE) panels ensure each chiller maintains a sustainable and long-lasting aesthetic.
Standard features include state-of-the-art weather protection for W-shaped coils, enhancing the high-efficiency operating life of the total chiller unit.
Remote air-cooled condensing
Remote location of the condenser can be a preferred option in many applications. Smardt can supply a full package if desired, or on a condenser-less basis. Either way, full warranty applies to all components supplied and commissioned.
Model Description | Brand | Nominal Capacity ton/kW | COP | Refrigerant Used | Compression Designation | Compressor Type | Hertz |
---|---|---|---|---|---|---|---|
AD028 to AD080 Economised | Smardt | 70RT - 226 tons 246 - 795 kW | 3.65 | R-134A | TT300; TT350 | CENTRIFUGAL | 50 |
AD086 to AD160 Standard & Economised | Smardt | 240RT - 400 tons 844 - 1,406 kW | 3.65 | R-134A | TT300; TT350 | CENTRIFUGAL | 50 |